| 引用本文: | 侯彦龙,杨校铃,陈义武,李莉莉,赵子轩,魏亮亮.脉冲流化床在氟化尾气高效回收中的工业应用[J].哈尔滨工业大学学报,2026,58(10):155.DOI:10.11918/202505058 |
| Hou Yanlong,Yang Xiaoling,Chen Yiwu,Li Lili,Zhao Zixuan,Wei Liangliang.Industrial application of pulsed fluidized bed for efficient recovery of fluorination tail gas[J].Journal of Harbin Institute of Technology,2026,58(10):155.DOI:10.11918/202505058 |
|
| |
|
|
| 本文已被:浏览 614次 下载 47次 |
 码上扫一扫! |
|
|
| 脉冲流化床在氟化尾气高效回收中的工业应用 |
|
侯彦龙1,2,杨校铃2,陈义武2,李莉莉1,赵子轩1,魏亮亮1,3
|
|
(1.哈尔滨工业大学 环境学院,哈尔滨 150090;2.中核四0四有限公司,兰州 732850; 3.城乡水资源与水环境全国重点实验室(哈尔滨工业大学),哈尔滨 150090)
|
|
| 摘要: |
| 针对天然铀生产氟化过程尾气中氟气过剩导致的资源浪费与环境污染问题,设计并研制了一套基于脉冲流化床系统的氟气回收的工艺,以实现物料自循环与氟气资源化利用。该工艺以四氟化铀(UF4)为吸收剂,通过分析氟气回收系统中不同反应温度、氟化尾气流量、物料停留时间等条件对氟气吸收率的影响,优化确定最佳工艺参数,并将最佳工艺参数应用于工业规模脉冲流化床。结果表明:系统内反应温度的提升有利于氟气吸收率的提高,但过高的温度会促进氟气与UF4反应生成六氟化铀(UF6),不利于氟气回收,故确定最佳反应温度为210~230 ℃;反应器中氟气的吸收率随氟化尾气流量增加而增大,氟气尾气流量建议控制在35 m3/h以下,最佳停留时间为1.33 h。氟气回收系统连续运行1个月,尾气中氟气体积分数从优化前的12%~15%降至0.01%。氟气与UO2发生反应转变为UO2F2是实现氟气回收的关键途径。本研究为核工业高浓度氟化尾气的高效回收与资源化处理提供了创新性解决方案。 |
| 关键词: 脉冲流化床 氟气回收 氟化尾气 工业应用 稳定性验证 |
| DOI:10.11918/202505058 |
| 分类号:TL94 |
| 基金项目:中核集团青年英才项目 |
|
| Industrial application of pulsed fluidized bed for efficient recovery of fluorination tail gas |
|
Hou Yanlong1,2,Yang Xiaoling2,Chen Yiwu2,Li Lili1,Zhao Zixuan1,Wei Liangliang1,3
|
|
(1.School of Environment, Harbin Institute of Technology, Harbin 150090, China; 2.The 404 Company Limited, China National Nuclear Corporation, Lanzhou 732850, China; 3.State Key Laboratory of Urban-rural Water Resource and Environment (Harbin Institute of Technology), Harbin 150090, China)
|
| Abstract: |
| To address the resource waste and environmental pollution problems caused by excessive fluorine gas in the fluorination tail gas of natural uranium production, this study designed and developed a fluorine gas recovery process based on a pulsed fluidized bed system to realize material self-circulation and fluorine gas resource utilization. This process used uranium tetrafluoride (UF4) as the absorbent. By analyzing the effects of different reaction temperatures, fluorination tail gas flow rates, material residence times, and other conditions on the absorption rate of fluorine gas in the fluorine gas recovery system, this paper optimized and determined the optimal process parameters, which were then applied to the industrial-scale pulsed fluidized bed. The results indicate that the increase of reaction temperature in the system is beneficial to the improvement of fluorine gas absorption rate, but excessively high temperature promotes the reaction between fluorine gas and UF4 to generate uranium hexafluoride (UF6), which is detrimental to fluorine gas recovery. Therefore, the optimal reaction temperature is determined to be 210-230 ℃. The absorption rate of fluorine gas in the reactor rises with the increase of fluorination tail gas flow rate. It is recommended to control the fluorination tail gas flow rate below 35 m3/h, and the optimal residence time is 1.33 h. When the fluorine gas recovery system was operated continuously for 1 month, the volume fraction of fluorine gas in the tail gas decreased from 12%-15% before optimization to 0.01%. The reaction of fluorine gas with UO2 to form UO2F2 is the key pathway to realize fluorine gas recovery. This paper provides an innovative solution for the efficient recovery and resource treatment of high-concentration fluorination tail gas in the nuclear industry. |
| Key words: pulsed fluidized bed fluorine gas recovery fluorination tail gas industrial application stability verification |
|
|
|
|