• Volume 58,Issue 10,2026 Table of Contents
    Select All
    Display Type: |
    • Bonding behavior of fiber-wound glass fiber reinforced polymer (GFRP) tube and concrete at arctic low temperatures

      2026, 58(10):1-12. DOI: 10.11918/202502011

      Abstract (401) HTML (20) PDF 10.53 M (91) Comment (0) Favorites

      Abstract:To investigate the bonding performance of fiber-wound glass fiber reinforced polymer (GFRP) tubes and concrete in polar and severe cold environments, a series of static push-out tests were conducted on 18 circular specimens and 14 square specimens. The study parameters included the low-temperature level (T), diameter-to-thickness ratio (D/t), fiber winding angle (θ), and interface treatment methods. The failure modes were observed during the tests, and the bonding stress-slip curves for each specimen were obtained. The influence of varying parameters on the interfacial bonding performance was analyzed. The results indicate that exposure to low temperatures significantly enhances the interface bonding performance, with the improvement in bonding performance being more pronounced for circular tubes compared to square tubes. As the temperature decreases, the bonding strength at the interface generally increases linearly. Specifically, when the temperature drops from 20 ℃ to -30 ℃, there is a notable enhancement in the anti-slip capacity at the interface; however, the bonding stiffness remains relatively unchanged under negative temperature conditions. In low-temperature conditions, the bonding strength of circular specimens shows a negative correlation with the diameter-to-thickness ratio (D/t), while the bonding strength of square specimens is less affected by D/t. Nevertheless, the bonding stiffness at the interface demonstrates an increasing trend that stabilizes as D/t decreases. Additionally, increasing the fiber winding angle contributes to improved interface bonding performance. Specimens with sand-coating exhibit substantially higher bond performance than uncoated specimens, with distinct characteristics observed in the frictional slip segments of their bonding slip curves. Based on the experimental results, a predictive model for the bonding strength of fiber-wound GFRP tube-concrete interfaces under polar low temperature is proposed, which can be utilized for the analysis and design of polar structural engineering.

      • 0+1
      • 1+1
      • 2+1
      • 3+1
      • 4+1
      • 5+1
      • 6+1
      • 7+1
      • 8+1
      • 9+1
      • 10+1
    • Fracture properties and analysis model of lightweight aggregate concrete considering effects of aggregate characteristics

      2026, 58(10):13-26. DOI: 10.11918/202502032

      Abstract (135) HTML (14) PDF 16.35 M (47) Comment (0) Favorites

      Abstract:The fracture behavior of lightweight aggregate concrete (LWAC) is significantly influenced by aggregate characteristics. To improve the fracture properties of LWAC and verify the applicability of established models, this paper conducted seventy three-point bending notched beam tests and adopted two methods to calculate the fracture energy (GF) of LWAC. The paper compared the applicability of the double-K fracture model (DKFM) and discrete particle fracture model (DPFM) and systematically analyzed the effect of lightweight aggregate′s average particle size (dave), volume fraction (Va), aggregate strength, and mortar water-binder ratio on the material′s GF and fracture toughness (KIc). Results indicate that the fracture paths of all groups of LWAC exhibit the characteristic of "aggregate penetration failure", and there exist significant differences in the toughening and crack-inhibiting mechanisms between lightweight and conventional aggregates. When dave≤10 mm, GF increases with the increase in dave. However, when dave>10 mm and Va>40%, the increase in internal defects of concrete results in a significant reduction in fracture properties. Enhancing aggregate strength can improve fracture properties, but the effect is limited. Significant discrepancies are observed between GF values calculated via different methods. Crack mouth opening displacement (GF-CMOD) is approximately 0.71 times that of the work of fracture method (GF-WFM). An aggregate characteristic-related function is proposed to modify the virtual crack coefficient βfic and characteristic crack length coefficient βch, and the predicted results of KIc-DPFM and KIc-DKFM are in good agreement.

      • 0+1
      • 1+1
      • 2+1
      • 3+1
      • 4+1
      • 5+1
      • 6+1
      • 7+1
      • 8+1
      • 9+1
      • 10+1
      • 11+1
      • 12+1
      • 13+1
    • Experiment on bond performance between engineered cementitious composite and steel bars

      2026, 58(10):27-38. DOI: 10.11918/202506056

      Abstract (102) HTML (19) PDF 21.96 M (37) Comment (0) Favorites

      Abstract:Engineered cementitious composite (ECC) is a high-performance material with strain-hardening and multiple-cracking properties under tensile loading. To provide a theoretical basis for the interfacial bond of ECC applied to force-bearing members, 21 reinforced ECC specimens were subjected to double pull-out tests, and the effects of ECC strength grade, bond length, and polyvinyl alcohol (PVA) fiber volume fraction on bond performance were investigated. During the test, the digital image correlation (DIC) technique was employed for non-contact full-field monitoring of the strain distribution on the ECC surface. Simultaneously, through the method of attaching strain gauges in rebar grooving and distributed optical fibers, the distribution curves of rebar strain and bond stress along the anchorage length were obtained. The results indicate that the fiber bridging effect effectively inhibits the propagation of microcracks in reinforced ECC specimens, and only one or two flat transverse cracks appear at the final failure of the specimens; the mechanical process of double pull-out specimens can be divided into elastic stage, crack formation stage, and stabilized cracking stage; under the same other parameters, the tensile contribution of the matrix material in reinforced ECC specimens is significantly higher than that in reinforced concrete specimens; at the same strain level, the load sustained by ECC increases with the increase in its strength grade and decreases with the increase in bond length; increasing the PVA fiber volume fraction provides a limited enhancement to the tensile contribution of ECC, and significant improvement is achieved only when the fraction reaches 2.5%. Compared with traditional reinforced concrete members, reinforced ECC members exhibit superior crack control ability and interfacial bond performance, showing good application prospects.

      • 0+1
      • 1+1
      • 2+1
      • 3+1
      • 4+1
      • 5+1
      • 6+1
      • 7+1
      • 8+1
      • 9+1
      • 10+1
      • 11+1
      • 12+1
      • 13+1
      • 14+1
      • 15+1
    • Algebraization of complex frequency equation of lumped damping string

      2026, 58(10):39-47. DOI: 10.11918/202502051

      Abstract (92) HTML (13) PDF 4.15 M (36) Comment (0) Favorites

      Abstract:A lumped damping string is commonly adopted as the simplest model for cable-viscous damper systems. However, its eigenproblem has long relied on numerical solutions or approximate analytical solutions in certain specific cases. For the analytical solution to this problem, this paper employed the exponential substitution method to derive an equivalent algebraic form of the complex frequency equation containing lumped damping at arbitrary terms and rational number locations. The results demonstrate that the fractional locations of the damping govern the degree of the derived algebraic equation, which in turn determines the number of solution branches for the original equation. Within each solution branch, there exist infinitely many solutions; the differences of their frequencies are determined by the highest degree of the algebraic equation; the vibration amplitude decays exponentially with a constant rate over time. When the algebraic equation is analytically solvable, it yields all closed-form analytical solutions for the original equation. This paper demonstrates that solving the eigenproblem for a lumped damping string at rational number locations is equivalent to solving an algebraic equation of the corresponding degree, meaning that both share the same computational complexity. The analytical method is independent of the string length, linear density, number of lumped dampers, and their damping coefficients in the simplified cable model. It applies to all rational number locations on the string. The correctness of the derived results is validated through comparison with solution methods in the literature.

      • 0+1
      • 1+1
      • 2+1
      • 3+1
      • 4+1
      • 5+1
    • Influence of support characteristics on the amplification coefficient of seismic response in porcelain column electrical equipment

      2026, 58(10):48-60. DOI: 10.11918/202502014

      Abstract (79) HTML (11) PDF 7.22 M (35) Comment (0) Favorites

      Abstract:The damage to porcelain column-type electrical equipment is a primary cause of power supply interruptions. The value of the dynamic amplification factor (DAF) for the support directly affects the seismic performance assessment of porcelain column-type electrical equipment. To determine the DAF for typical porcelain column-type electrical equipment, this paper proposes a distributed parameter model that considers the bending stiffness of flanges. This model provides the frequency equation and the equation of motion balance under generalized support excitation for the support-equipment system. The accuracy of the simplified analytical model is validated by comparing its results with vibration test data from three typical porcelain column-type electrical devices and computational results from multi-degree-of-freedom models. Using the simplified analytical model, the influences of parameters such as the height ratio, mass ratio, stiffness ratio, and flange bending stiffness ratio on the natural frequency of the support-equipment system and the DAF for the equipment are analyzed. The results indicate that the height and cross-sectional dimensions of the support have the most significant impact on the DAF for the equipment. Specifically, the DAF increases as the height of the support increases and the cross-sectional dimensions decrease. Current code recommendations for support dynamic amplification factors tend to be conservative (i.e., understated). Based on the requirements for support height and stiffness specified in the standards, it is recommended that the DAF for brackets supporting double porcelain columns and porcelain column-type electrical equipment with oil tanks located at the bottom be set to 2.5. For porcelain column-type electrical equipment with oil tanks located at the top, the suggested DAF is 1.5.

      • 0+1
      • 1+1
      • 2+1
      • 3+1
      • 4+1
      • 5+1
      • 6+1
      • 7+1
      • 8+1
      • 9+1
      • 10+1
      • 11+1
      • 12+1
      • 13+1
      • 14+1
      • 15+1
    • Damage of reinforced concrete frame structures using integral damage model of element material

      2026, 58(10):61-71. DOI: 10.11918/202502013

      Abstract (93) HTML (15) PDF 16.39 M (41) Comment (0) Favorites

      Abstract:Aiming at the problem of low accuracy of traditional damage indices when evaluating the damage degree of reinforced concrete (RC) frame structures under three-dimensional (3D) ground motion loading, this paper presented a storey seismic damage assessment model for RC frame structures based on the integral of element material, namely damage indices of integration of element material (Diem). Based on the existing material damage indices of concrete and steel bar, this model adopted the weighted average method considering the distance from the centroidal axis to construct the plastic hinge section damage index with directional properties. On this basis, it further constructed a damage model for a single RC frame column based on damage weighting and a storey damage model combining mixed weighting of damage and axial force. Taking an actually seismically damaged RC frame structure as the analysis object, this paper performed nonlinear incremental dynamic analysis (IDA) using OpenSEES software and utilized the self-compiled program to conduct Diem-based damage analysis for single columns and weak storeys based on the column curvature and axial force data output by OpenSEES. The results show that the damage degrees of single frame columns and storeys calculated by the Diem model are consistent with actual seismic damage. The "damage ring" obtained through calculation using the directional property of Diem is consistent with the residual drift direction of actual seismic damage and can effectively characterize the structural damage evolution characteristics in different directions. The Diem damage model is suitable for refined damage assessment of RC structures under actual 3D ground motion.

      • 0+1
      • 1+1
      • 2+1
      • 3+1
      • 4+1
      • 5+1
      • 6+1
      • 7+1
      • 8+1
      • 9+1
      • 10+1
      • 11+1
      • 12+1
      • 13+1
      • 14+1
      • 15+1
      • 16+1
      • 17+1
      • 18+1
      • 19+1
      • 20+1
    • A smart washer sensor based on a novel sensitivity-enhanced structure for monitoring tightening force of high-strength bolts

      2026, 58(10):72-81. DOI: 10.11918/202506042

      Abstract (118) HTML (18) PDF 10.60 M (39) Comment (0) Favorites

      Abstract:High-strength bolted connections are widely used in various engineering structures, and connection loosening caused by the attenuation of bolt tightening force may pose a serious threat to structural safety. Pressure washers are commonly used sensors for monitoring bolt tightening force. However, for high-strength bolts subjected to large loads, traditional pressure washers have drawbacks such as large sensor size and measurement accuracy that is easily affected by factors including load eccentricity and friction between the sensor and the structural surface, making it difficult to meet the requirements of engineering applications. To address this issue, this paper proposed a smart washer sensor with a novel sensitivity-enhanced structure for monitoring the tightening force of high-strength bolts. Different from traditional pressure washers using a single ring-shaped structure, the proposed smart washer consists of three layers of stacked ring-shaped structures, and the contact surfaces between the middle measuring unit and the upper/lower force transmission units are inwardly tilted annular surfaces. This original sensitivity-enhanced structure converts the vertical bolt pressure on the smart washer into horizontal circumferential expansion deformation of the middle measuring unit, which not only significantly increases the measurement sensitivity of the smart washer but also eliminates the adverse effects of friction between the smart washer and the structural contact surface on measurement accuracy. Through theoretical analysis and numerical simulation, the influence rules of the design parameters of the smart washer on its key measurement indicators such as sensitivity and measurement range were investigated, and a segmented measurement model for the entire loading and unloading processes of the smart washer was proposed. This model solved the problem of inconsistent measurement results during the loading and unloading processes of the smart washer caused by friction between the tilted contact surfaces and further improved the measurement accuracy. Finally, a smart washer sensor with a measurement range of 700 kN was fabricated and tested. The experimental results indicate that the average measurement error of the sensor is only 3 kN. The proposed smart washer sensor has the advantages of small volume, large measurement range, and high accuracy, which has broad engineering application prospects.

      • 0+1
      • 1+1
      • 2+1
      • 3+1
      • 4+1
      • 5+1
      • 6+1
      • 7+1
      • 8+1
      • 9+1
      • 10+1
      • 11+1
      • 12+1
      • 13+1
      • 14+1
      • 15+1
      • 16+1
      • 17+1
    • Large-scale shaking table test study on seismic performance of geocellular retaining walls with different cross-sectional types

      2026, 58(10):82-94. DOI: 10.11918/202411024

      Abstract (97) HTML (9) PDF 26.62 M (47) Comment (0) Favorites

      Abstract:A comparative shaking table test was conducted to investigate the seismic performance of geocell retaining walls with different cross-sectional configurations, specifically the layered stacking type and the spaced type. By applying various ground motion inputs, the response characteristics of the two wall types under seismic loading were analyzed in terms of geocell confining pressure, acceleration amplification coefficient, and horizontal displacement of the wall surface. The results show that there are differences in seismic performance between the two models under earthquake loading. The spaced retaining wall saves about 20% in material; although its seismic performance is weaker than that of the layered retaining wall, the 1.2g time-interval retaining wall still has enough strength and stiffness to maintain the stability of the slope. Both models exhibit increasing peak values of cellular confining pressure and horizontal displacement with the increase of the amplitude. The acceleration amplification coefficient of the layered retaining wall shows an amplification effect with elevation, while the opposite trend is observed for the spaced retaining wall. At frequencies ranging from 1 Hz to 4 Hz, the three seismic indexes of the two models decrease with the increase of frequency, while gradually increase beyond 4 Hz. The dynamic response degree of both retaining walls under X-direction and XZ-direction vibrations are generally similar, although the responses are more significant when the vibration is in X-direction. The failure process of both models can be divided into three stages: vibration compaction, convex rotation and coupling failure. The residual displacement of the 1.0g time interval retaining wall is larger than that of the laminated building, reaching 2.38% of the wall height, which does not meet the failure criterion. The installation of short geocell layers at the upper section enhances the stability of the superstructure, with preferred positions at 14H/6,0H/6,7H/16 and 5H/16. The research results provide valuable guidance for seismic design and cross-sectional optimization of geotechnical retaining walls.

      • 0+1
      • 1+1
      • 2+1
      • 3+1
      • 4+1
      • 5+1
      • 6+1
      • 7+1
      • 8+1
      • 9+1
      • 10+1
      • 11+1
      • 12+1
      • 13+1
      • 14+1
      • 15+1
      • 16+1
      • 17+1
      • 18+1
      • 19+1
      • 20+1
      • 21+1
      • 22+1
      • 23+1
      • 24+1
    • Mechanical performance of cold-formed steel web-stiffened double-limb built-up short columns

      2026, 58(10):95-107. DOI: 10.11918/202507056

      Abstract (94) HTML (14) PDF 14.58 M (62) Comment (0) Favorites

      Abstract:To study the mechanical performance of cold-formed steel web-stiffened double-limb built-up short columns, the effects of parameters, such as the web height-to-thickness ratio, stiffening angle, flange width-to-thickness ratio, and screw spacing, on the mechanical properties of members were systematically investigated by combining experimental research, numerical simulation, and theoretical analysis. In addition, the prediction results of bearing capacity from the effective width method and the direct strength method in the Chinese code GB/T 50018—2025 and the North American code AISI S100—2016 were compared. The results show that the specimens mainly undergo distortional buckling and distortional-local interactive buckling; the ultimate bearing capacity increases with the increase of stiffening angle and flange width-to-thickness ratio, and the maximum improvements reach 22.09% and 19.46% at stiffening angles of 10° and 20°, respectively; the increase in web height-to-thickness ratio leads to a significant decrease in bearing capacity, with a decrease ranging from 9.45% to 22.42%; the screw spacing has a more significant impact on the ultimate bearing capacity of medium-to-long columns (such as 2 000 mm and 2 500 mm specimens); the calculation results of bearing capacity using the effective width method in the North American code AISI S100—2016 are closer to the experimental results, while the effective width method in the Chinese code GB/T 50018—2025 and the direct strength method in the North American code AISI S100—2016 are both conservative. On this basis, the code methods were modified by combining the experimental and finite element data, a more accurate calculation method for bearing capacity was proposed, and its reliability was verified. The proposed calculation method takes into account both the stiffening effect and the built-up effect and has good prediction accuracy and applicability, providing a theoretical basis for the revision of relevant codes and design practice.

      • 0+1
      • 1+1
      • 2+1
      • 3+1
      • 4+1
      • 5+1
      • 6+1
      • 7+1
      • 8+1
      • 9+1
      • 10+1
      • 11+1
      • 12+1
      • 13+1
      • 14+1
    • A low-cycle fatigue model of Q690D high-strength steel

      2026, 58(10):108-114. DOI: 10.11918/202504074

      Abstract (80) HTML (8) PDF 4.15 M (26) Comment (0) Favorites

      Abstract:In order to calculate the low-cycle fatigue life of high-strength steel under high strain amplitudes (such as strong earthquakes), this paper described the rate of the initiation and stable propagation area of a low-cycle fatigue crack in high-strength steel as an increasing power function of the number of cyclic loading cycles. By integrating the accelerated growth equations of the crack initiation area and the stable propagation area under low-cycle fatigue, a low-cycle fatigue model for high-strength steel was derived to uniformly calculate the fatigue crack initiation and stable propagation life. By using an ellipsoidal fracture model as a criterion for unstable propagation of the low-cycle fatigue crack and crack tip cracking in high-strength steel, the propagation of the low-cycle fatigue crack in a round rod made of Q690D high-strength steel under different high strain amplitudes (±0.5%, ±1.5%, ±2.0%, ±2.5%, and ±3.0%) was calculated theoretically and simulated numerically. As a consequence, the initiation and stable propagation areas of the low-cycle fatigue crack in the round rod made of Q690D high-strength steel under different high strain amplitudes were calculated. The paper established a function that satisfies the stress boundary conditions, linking the low-cycle life model parameters of high-strength steel to the nominal maximum normal stress under the maximum fatigue load and the normal stress amplitude under the fatigue load amplitude on the fatigue fracture surface. Based on the low-cycle fatigue test life of the round rod made of Q690D high-strength steel and the numerically calculated crack initiation and stable propagation area under low-cycle fatigue, the low-cycle fatigue life calculation formula for the round rod made of Q690D high-strength steel under different high strain amplitudes was calibrated. The calculation results show that the calculation error of the calibrated low-cycle fatigue life calculation formula for the round rod made of Q690D high-strength steel ranges from -26.1% to -2.7%.

      • 0+1
      • 1+1
      • 2+1
      • 3+1
      • 4+1
      • 5+1
    • Research progress on design and optimization of catalysts for electrocatalytic urea synthesis from CO2 and nitrogen sources

      2026, 58(10):115-131. DOI: 10.11918/202504056

      Abstract (112) HTML (11) PDF 14.85 M (45) Comment (0) Favorites

      Abstract:Urea is one of the most widely used fertilizers in agricultural production. However, traditional industrial urea synthesis processes require massive energy inputs, causing environmental pollution and carbon emissions. With the continuous advancement of the goals of "carbon peaking and carbon neutrality" and constraints of the ecological environment, green and sustainable electrocatalytic C—N coupling routes for urea synthesis have become a research hotspot in recent years. Although there have been extensive reports on the design and synthesis, optimization strategies, and reaction mechanisms of C—N coupling catalysts, this field still lacks a systematic framework that systematically summarizes electrocatalytic urea synthesis catalysts based on core optimization strategies. By systematically reviewing the reaction mechanisms and typical reaction devices for the electrocatalytic co-reduction of CO2 and different nitrogen sources, this paper proposed a classification system for catalyst optimization strategies centering on "component synergism, defect modulation, and structural optimization" and deeply discussed the design concepts and modification directions of various catalysts. It pointed out that multi-metal sites with synergistic effects, multifunctional carriers, and special structures capable of optimizing active sites are the keys to enhancing catalytic performance. This paper summarized and prospected the core challenges and future development directions in this field and emphasized the importance of promoting the resource utilization of industrial wastes. This research not only provides new theoretical perspectives and analytical frameworks for promoting the application of electrocatalytic urea synthesis but also is expected to guide the development of new-generation high-efficiency catalysts and accelerate the industrialization process of electrocatalytic urea synthesis technology.

      • 0+1
      • 1+1
      • 2+1
      • 3+1
      • 4+1
      • 5+1
      • 6+1
      • 7+1
      • 8+1
    • Application status of wastewater desalination and water resource reuse technologies in China′s steel industry

      2026, 58(10):132-142. DOI: 10.11918/202503025

      Abstract (98) HTML (14) PDF 2.44 M (39) Comment (0) Favorites

      Abstract:The steel industry is typically characterized by high water consumption and substantial wastewater discharge. Its production process generates a large volume of comprehensive wastewater, characterized by complex composition, high salinity, and significant fluctuations in water quality and quantity. Achieving effective desalination and reuse of such wastewater is essential for reducing fresh water intake, enhancing water resource recycling rates, and promoting green and sustainable development in the field. According to the existing engineering application cases and published related studies, this paper introduced the sources and characteristics of comprehensive wastewater in steel plants. Then, it systematically elaborated on the principles, advantages and disadvantages, applications, and techno-economic feasibility of mainstream desalination methods, including reverse osmosis, ion exchange, nanofiltration, electro-adsorption, electrodialysis, and electro-deionization, as well as their combination processes. Furthermore, this paper summarized the current application status of desalination and reuse technologies in China′s steel plants. Finally, by incorporating field data from typical steel plants, a comparative analysis was conducted on the actual performance and operational costs of commonly used desalination and reuse processes (such as dual-membrane methods and electro-adsorption). Based on the findings, targeted recommendations were proposed for the future development of desalination and water reuse technologies in steel plants. This review aims to provide foundation support for the selection and optimization of desalination technologies for comprehensive wastewater in the steel industry.

      • 0+1
      • 1+1
      • 2+1
    • Impact of combined pollution on microbial communities and antibiotic resistance genes in activated sludge

      2026, 58(10):143-154. DOI: 10.11918/202506051

      Abstract (77) HTML (7) PDF 11.78 M (32) Comment (0) Favorites

      Abstract:Polyhalogenated 9H-carbazoles and nanomaterials are frequently detected emerging contaminants in aquatic environments. Given the unknown impact of their combined pollution on microbial communities and antibiotic resistance genes (ARGs) in activated sludge systems, this study investigated the responses of microbial communities and ARGs to combined pollution using high-throughput sequencing, gene prediction, and network analysis under the stress conditions of 3-bromocarbazole (3-BCZ) at low (0.05 mg/L) and high (5 mg/L) mass concentrations and Fe3O4 nanoparticles (Fe3O4 NPs) at 1 mg/L. The results indicate that high-mass-concentration 3-BCZ and Fe3O4 NPs combined stress reduces bacterial community diversity and significantly alters bacterial community structure. Abundant genera alter under different Fe3O4 NPs and 3-BCZ stress conditions, while rare genera remain relatively stable. TM7a (12.82%–23.89%) is the dominant genus in all stressed samples. Moderate and rare taxa are the dominant taxa in microbial interaction networks under single and combined stress, respectively, but their core genera are different, among which Defluviicoccus and Nitrospira are the core genera under combined pollution stress. High-concentrationcombined pollution promotes the enrichment of specific nitrogen removal functional bacteria (such as Nitrosomonas, Nitrospira, Acidovorax, and Hydrogenophaga) and increases the abundance of some nitrogen metabolism functional genes (such as nirKS andnosZ). A total of eight ARG types (68 subtypes) are detected, among which β-lactams (Beta-lactam), efflux pumps (Other/efflux), and fluoroquinolone-florfenicol-chloramphenicol (FCA) arethe dominant types. Fe3O4 NPs and 3-BCZ combined pollution stress increases the abundance of Beta-lactam (such as cfxA and penA) and FCA (such as adeA/cmeA and EmrB/QacA) ARGs. ARGs exhibit complex co-occurrence patterns under both single and combined pollution stress, and their core ARGs are all Other/efflux types (such as mdtE/yhiU and norB/norC). This study reveals the response differences of abundant and rare genera and ARGs under combined pollution of polyhalogenated 9H-carbazoles and nanomaterials and provides theoretical support and technical guidance for microbial community regulation and the development of highly resilient new processes in wastewater treatment systems under combined pollution stress of emerging contaminants.

      • 0+1
      • 1+1
      • 2+1
      • 3+1
      • 4+1
      • 5+1
    • Industrial application of pulsed fluidized bed for efficient recovery of fluorination tail gas

      2026, 58(10):155-161. DOI: 10.11918/202505058

      Abstract (84) HTML (10) PDF 4.81 M (26) Comment (0) Favorites

      Abstract:To address the resource waste and environmental pollution problems caused by excessive fluorine gas in the fluorination tail gas of natural uranium production, this study designed and developed a fluorine gas recovery process based on a pulsed fluidized bed system to realize material self-circulation and fluorine gas resource utilization. This process used uranium tetrafluoride (UF4) as the absorbent. By analyzing the effects of different reaction temperatures, fluorination tail gas flow rates, material residence times, and other conditions on the absorption rate of fluorine gas in the fluorine gas recovery system, this paper optimized and determined the optimal process parameters, which were then applied to the industrial-scale pulsed fluidized bed. The results indicate that the increase of reaction temperature in the system is beneficial to the improvement of fluorine gas absorption rate, but excessively high temperature promotes the reaction between fluorine gas and UF4 to generate uranium hexafluoride (UF6), which is detrimental to fluorine gas recovery. Therefore, the optimal reaction temperature is determined to be 210-230 ℃. The absorption rate of fluorine gas in the reactor rises with the increase of fluorination tail gas flow rate. It is recommended to control the fluorination tail gas flow rate below 35 m3/h, and the optimal residence time is 1.33 h. When the fluorine gas recovery system was operated continuously for 1 month, the volume fraction of fluorine gas in the tail gas decreased from 12%-15% before optimization to 0.01%. The reaction of fluorine gas with UO2 to form UO2F2 is the key pathway to realize fluorine gas recovery. This paper provides an innovative solution for the efficient recovery and resource treatment of high-concentration fluorination tail gas in the nuclear industry.

      • 0+1
      • 1+1
      • 2+1
      • 3+1
      • 4+1
      • 5+1
      • 6+1
      • 7+1
    • Decarbonization characteristics of coal combustion flue gas based on a novel ammonia method

      2026, 58(10):162-170. DOI: 10.11918/202505005

      Abstract (94) HTML (17) PDF 6.28 M (37) Comment (0) Favorites

      Abstract:Ammonia-based carbon capture is among the most promising flue-gas CO2 capture technologies, yet high energy consumption for solvent regeneration remains a key barrier to industrial deployment. To address this, a novel ammonia-based process was investigated in which ethanol is used to partially replace water in the solvent to promote the solvo-crystallization of NH4HCO3; crystalline regeneration is expected to reduce the energy required for CO2 recovery. Under the concentration of 14% CO2 and 4.16 mol/L of ammonia, the CO2 absorption characteristics at different temperatures and ethanol concentrations were studied by bubble reactor. The physicochemical structure of crystallization was analyzed and the influence of residence time on the particle distribution was explored. The results show that 10-15 ℃ is the optimal temperature for the new ammonia-based method. The CO2 removal rate is 64.8% and the volumetric mass transfer coefficient reaches 3.44×10-4 mol/(m3·s·Pa) at the stable absorption section. Increasing the ethanol volume fraction from 30% to 50% enhanced the solvent CO2 removal efficiency by 10.44% and increased the overall volumetric mass transfer coefficient by 8.86%. The addition of ethanol is beneficial for the occurrence of crystallization in the flue gas-ammonia-ethanol system. Spontaneous nucleation occurred after 60 minutes of reaction, and a CO2 loading capacity of the absorbent reaches 0.521 7, equivalent to a CO2 absorption capacity of 1.35 kg CO2 per kg NH3; extending the residence time of crystallization can improve the surface morphology and growth of crystals, which is beneficial for crystal stability and solid-liquid separation. Scanning electron microscopy (SEM) results show that defects exist after 30 minutes of crystal growth. The XRD analysis indicates that the main component of the crystallization product is ammonium bicarbonate.

      • 0+1
      • 1+1
      • 2+1
      • 3+1
      • 4+1
      • 5+1
      • 6+1
      • 7+1
      • 8+1
    • Performance and energy-saving analysis of temperature-adaptive radiative cooling coatings

      2026, 58(10):171-180. DOI: 10.11918/202504084

      Abstract (109) HTML (14) PDF 9.88 M (70) Comment (0) Favorites

      Abstract:Daytime radiative cooling technology reflects the energy of the solar wavelength band (0.3-2.5 μm) strongly and exchanges energy with outer space at a temperature of 3 K through the "atmospheric window" (8-13 μm), achieving cooling below the ambient temperature without additional energy input. However, existing radiative cooling technology also strongly reflects solar wavelength energy in cold winters, dramatically increasing the energy consumption of building heating. This study prepared a temperature-adaptive radiative cooling coating with phase change and temperature control function. Through the reversible opening and closing reaction of crystalline violet lactone at different temperatures, a solar reflectance control range of 33% within 10-40 ℃ was achieved, with a solar reflectance of 92% in summer and 59% in winter. Actual building tests show that after applying this coating, the average indoor temperature in summer is reduced by 3 ℃, and that in winter is reduced by only 0.1 ℃. According to calculations, the annual carbon reduction rate in Chongqing after applying the coating is 15.7%, which is 5.0% higher than that of the traditional radiative cooling coating, and it can effectively reduce peak electricity loads and reduce power grid operation and expansion costs. The coating is simple to prepare and inexpensive, breaking through the geographical limitations of traditional radiative cooling coatings that are only suitable for some warm and hot regions. It has excellent cross-climate applicability and can be used on a large scale in most cities where the hot and cold load ratio is greater than 0.05.

      • 0+1
      • 1+1
      • 2+1
      • 3+1
      • 4+1
      • 5+1
      • 6+1
      • 7+1
      • 8+1
      • 9+1
    • Thermo-hygrometric characteristics of variable-frequency heat pump dehumidification unit with condensater heat recovery for shipbuilding

      2026, 58(10):181-187. DOI: 10.11918/202503017

      Abstract (88) HTML (18) PDF 8.68 M (32) Comment (0) Favorites

      Abstract:The shipbuilding industry faces challenges with low dehumidification efficiency, high energy consumption, and imprecise air supply control under high-temperature and high-humidity conditions. To address these challenges, this study developed a condensater heat recovery variable-frequency heat pump dehumidification unit and systematically evaluated its performance. The unit applied a dual-condenser parallel structure and a full-variable frequency control strategy, enabling the regulation of multi-parameters. A testing platform based on enthalpy difference laboratory was established to simulate a typical shipbuilding environment, i.e., at 35 ℃ and 70% relative humidity. The effects of compressor speed, heat exchange distribution between the two condensers, condenser fan frequency, and air supply velocity on the dehumidification performance were comprehensively examined. The performance was quantitatively assessed by coefficient of performance (COP) and specific moisture extraction rate (SMER). The results showed that optimal performance with COP of 4.36 and SMER of 4.01 kg/kWh was achieved at a compressor speed of 3 500 r/min, a condenser fan frequency of 30 Hz, a condenser heat exchange ratio of 5.17∶1, and an air supply velocity of 2.7 m/s. The unit demonstrated precise control of temperature and humidity under various operational conditions and exhibited excellent energy efficiency. The findings will provide an effective and energy-saving technical solution for industrial applications requiring strict humidity control, such as shipbuilding, and offer both theoretical and experimental support for the design and optimization of industrial dehumidification systems.

      • 0+1
      • 1+1
      • 2+1
      • 3+1
      • 4+1
      • 5+1
      • 6+1
      • 7+1
      • 8+1
      • 9+1
      • 10+1
      • 11+1
    • Second-order discontinuous finite element characteristic-line coupled method for neutron transport calculations

      2026, 58(10):188-194. DOI: 10.11918/202504076

      Abstract (81) HTML (10) PDF 4.07 M (48) Comment (0) Favorites

      Abstract:The axial function expansion method for neutron transport offers a novel full-core, high-fidelity transport calculation approach with the advantage of stable iterative convergence, avoiding the numerical instabilities that traditional 2D/1D methods may encounter under strongly heterogeneous conditions. However, most existing axial expansion implementations use only first-order (linear) axial trial functions; achieving sufficient accuracy therefore requires very fine axial meshes, leading to a substantial increase in the number of axial layers and high memory usage. To address this issue, this paper extends the axial expansion to second-order (quadratic) trial functions. Analytical solutions for the inverse and matrix exponential of the resulting 3×3 coefficient matrix are derived, and the performance of the second-order solver is implemented and validated on the 3D C5G7 international benchmark. The results demonstrate that with relatively coarse axial meshes, the quadratic approximation significantly improves the pin-wise power calculation accuracy (reducing the relative power error to about 1/2-1/5 of that of the first-order method), and decreases the number of axial layers required to achieve equivalent accuracy to roughly one-third of that needed by the linear method, thereby reducing the memory requirement by roughly 50%. Concurrently, the quadratic method also retains stable iterative convergence behavior. However, due to the diminished effectiveness of the conventional coarse-mesh finite-difference (CMFD) acceleration scheme on large axial mesh cells, the quadratic approximation requires more iterations to converge than the first-order method, so no significant reduction in total computing time was observed. In summary, the proposed second-order axial expansion method maintains high-fidelity in whole-core transport calculation accuracy while substantially lowering the mesh density and memory demand, which is of great significance for the development of efficient high-fidelity reactor-physics simulation tools.

      • 0+1
      • 1+1
      • 2+1
    • Status and prospects of dynamic sensing and quantitative detection technologies for icing characteristics

      2026, 58(10):195-228. DOI: 10.11918/202508071

      Abstract (106) HTML (14) PDF 22.71 M (61) Comment (0) Favorites

      Abstract:Ice formation is widespread in industrial and natural environments and often causes various adverse effects such as equipment failures and traffic hazards. This paper systematically reviewed the classification, principles, and development trends of existing ice detection technologies, and horizontally compared the detection ranges and accuracy indicators of contact and non-contact ice detection sensors under each property based on the classification of five physical properties of ice, namely, acoustics, optics, thermology, electricity, and mechanics. The analysis results show that acoustic and optical contact ice detection technologies are applicable to the detection of ice layers or water films at the micrometer to millimeter scale, achieving a maximum thickness resolution of 8 μm, which can meet the detection requirements of 0.3 mm ice layers on aircraft surfaces. Significant scattering and interference induced by micro-scale bubbles and brine channels within ice reduce the thickness detection accuracy, but simultaneously provide a quantifiable acoustic identification basis for ice type differentiation. Thermal contact ice detection technologies achieve detection by monitoring the latent heat release at the moment of freezing or the changes in thermal resistance and heat capacity of the ice body, but it is difficult to precisely distinguish millimeter-level thickness differences and different ice types. Electrical and mechanical contact ice detection technologies can stably achieve an ice layer thickness detection accuracy of 0.10.3 mm; wind tunnel experiments show that they can distinguish ice layers of 0.060.45 mm, and they have been widely used in ice monitoring of aircraft and roads. For the non-contact real-time monitoring requirements of centimeter-level ice thickness on wind turbine blades and transmission lines, camera-based ice detection technologies with a detection accuracy of 110 mm are mostly adopted. The meter-level sea ice detection required for polar scientific expeditions and maritime transportation relies on microwave and LiDAR remote sensing technologies with a spatial resolution of 1 m and the capabilities of ice-water differentiation and dynamic inversion of ice thickness, providing key safety guarantee data. Furthermore, the optimization paths of existing methods in improving the coupling accuracy of multiple schemes and enhancing the generalization ability of intelligent algorithms were further refined, providing theoretical support and practical paths for the prevention and control of ice disasters in key infrastructure such as aerospace vehicles, cold region power grids, and offshore wind power. In the future, ice detection technologies will integrate multimodal sensing technologies such as acoustic, optical, thermal, electrical, and mechanical sensing to achieve high-precision dynamic detection of multiple parameters, including ice type, ice thickness, and ice area.

      • 0+1
      • 1+1
      • 2+1
      • 3+1
      • 4+1
      • 5+1
      • 6+1
      • 7+1
      • 8+1
      • 9+1
      • 10+1
      • 11+1
      • 12+1
      • 13+1
      • 14+1
      • 15+1
      • 16+1
      • 17+1
      • 18+1
      • 19+1
      • 20+1
      • 21+1
      • 22+1

Current Issue


Volume , No.

Table of Contents

Archive

Volume

Issue

Most Read

Most Cited

Download Ranking