Large-scale shaking table test study on seismic performance of geocellular retaining walls with different cross-sectional types
CSTR:
Author:
Affiliation:

(1.School of Highway Engineering, Chang′an University, Xi′an 710064, China; 2.Key Laboratory of lntelligent Construction and Maintenance of CAAC(Chang′an University), Xi′an 710064, China; 3.Xi′an Key Laboratory of Geotechnical Engineering for Green and Intelligent Transport(Chang′an University), Xi′an 710064, China)

Clc Number:

TU476.4

Fund Project:

undefined

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    A comparative shaking table test was conducted to investigate the seismic performance of geocell retaining walls with different cross-sectional configurations, specifically the layered stacking type and the spaced type. By applying various ground motion inputs, the response characteristics of the two wall types under seismic loading were analyzed in terms of geocell confining pressure, acceleration amplification coefficient, and horizontal displacement of the wall surface. The results show that there are differences in seismic performance between the two models under earthquake loading. The spaced retaining wall saves about 20% in material; although its seismic performance is weaker than that of the layered retaining wall, the 1.2g time-interval retaining wall still has enough strength and stiffness to maintain the stability of the slope. Both models exhibit increasing peak values of cellular confining pressure and horizontal displacement with the increase of the amplitude. The acceleration amplification coefficient of the layered retaining wall shows an amplification effect with elevation, while the opposite trend is observed for the spaced retaining wall. At frequencies ranging from 1 Hz to 4 Hz, the three seismic indexes of the two models decrease with the increase of frequency, while gradually increase beyond 4 Hz. The dynamic response degree of both retaining walls under X-direction and XZ-direction vibrations are generally similar, although the responses are more significant when the vibration is in X-direction. The failure process of both models can be divided into three stages: vibration compaction, convex rotation and coupling failure. The residual displacement of the 1.0g time interval retaining wall is larger than that of the laminated building, reaching 2.38% of the wall height, which does not meet the failure criterion. The installation of short geocell layers at the upper section enhances the stability of the superstructure, with preferred positions at 14H/6,0H/6,7H/16 and 5H/16. The research results provide valuable guidance for seismic design and cross-sectional optimization of geotechnical retaining walls.

    Reference
    Related
    Cited by
Get Citation
Related Videos

Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:November 13,2024
  • Revised:
  • Adopted:
  • Online: October 27,2026
  • Published:
Article QR Code