Experiment on bond performance between engineered cementitious composite and steel bars
CSTR:
Author:
Affiliation:

(1.School of Mechanics and Civil Engineering, China University of Mining and Technology (Beijing), Beijing 100083, China; 2.Beijing Key Laboratory of Municipal Infrastructure Modelling and Resilience Enhancement, Beijing 100083, China; 3.Railway Engineering Research Institute, China Academy of Railway Sciences Corporation Limited, Beijing 100081, China)

Clc Number:

TU391

Fund Project:

undefined

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Engineered cementitious composite (ECC) is a high-performance material with strain-hardening and multiple-cracking properties under tensile loading. To provide a theoretical basis for the interfacial bond of ECC applied to force-bearing members, 21 reinforced ECC specimens were subjected to double pull-out tests, and the effects of ECC strength grade, bond length, and polyvinyl alcohol (PVA) fiber volume fraction on bond performance were investigated. During the test, the digital image correlation (DIC) technique was employed for non-contact full-field monitoring of the strain distribution on the ECC surface. Simultaneously, through the method of attaching strain gauges in rebar grooving and distributed optical fibers, the distribution curves of rebar strain and bond stress along the anchorage length were obtained. The results indicate that the fiber bridging effect effectively inhibits the propagation of microcracks in reinforced ECC specimens, and only one or two flat transverse cracks appear at the final failure of the specimens; the mechanical process of double pull-out specimens can be divided into elastic stage, crack formation stage, and stabilized cracking stage; under the same other parameters, the tensile contribution of the matrix material in reinforced ECC specimens is significantly higher than that in reinforced concrete specimens; at the same strain level, the load sustained by ECC increases with the increase in its strength grade and decreases with the increase in bond length; increasing the PVA fiber volume fraction provides a limited enhancement to the tensile contribution of ECC, and significant improvement is achieved only when the fraction reaches 2.5%. Compared with traditional reinforced concrete members, reinforced ECC members exhibit superior crack control ability and interfacial bond performance, showing good application prospects.

    Reference
    Related
    Cited by
Get Citation
Related Videos

Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:June 23,2025
  • Revised:
  • Adopted:
  • Online: October 27,2026
  • Published:
Article QR Code