Bonding behavior of fiber-wound glass fiber reinforced polymer (GFRP) tube and concrete at arctic low temperatures
CSTR:
Author:
Affiliation:

(1.School of Civil Engineering, Tianjin University, Tianjin 300354, China; 2.Key Laboratory of Coast Civil Structure Safety(Tianjin University), Ministry of Education, Tianjin 300354, China; 3.Beijing Engineering Research Center of Existing Building Renovation (Tianjin Branch), Tianjin 300354, China; 4.China Architecture Design and Research Group, Beijing 100044, China)

Clc Number:

TU398.9

Fund Project:

undefined

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    To investigate the bonding performance of fiber-wound glass fiber reinforced polymer (GFRP) tubes and concrete in polar and severe cold environments, a series of static push-out tests were conducted on 18 circular specimens and 14 square specimens. The study parameters included the low-temperature level (T), diameter-to-thickness ratio (D/t), fiber winding angle (θ), and interface treatment methods. The failure modes were observed during the tests, and the bonding stress-slip curves for each specimen were obtained. The influence of varying parameters on the interfacial bonding performance was analyzed. The results indicate that exposure to low temperatures significantly enhances the interface bonding performance, with the improvement in bonding performance being more pronounced for circular tubes compared to square tubes. As the temperature decreases, the bonding strength at the interface generally increases linearly. Specifically, when the temperature drops from 20 ℃ to -30 ℃, there is a notable enhancement in the anti-slip capacity at the interface; however, the bonding stiffness remains relatively unchanged under negative temperature conditions. In low-temperature conditions, the bonding strength of circular specimens shows a negative correlation with the diameter-to-thickness ratio (D/t), while the bonding strength of square specimens is less affected by D/t. Nevertheless, the bonding stiffness at the interface demonstrates an increasing trend that stabilizes as D/t decreases. Additionally, increasing the fiber winding angle contributes to improved interface bonding performance. Specimens with sand-coating exhibit substantially higher bond performance than uncoated specimens, with distinct characteristics observed in the frictional slip segments of their bonding slip curves. Based on the experimental results, a predictive model for the bonding strength of fiber-wound GFRP tube-concrete interfaces under polar low temperature is proposed, which can be utilized for the analysis and design of polar structural engineering.

    Reference
    Related
    Cited by
Get Citation
Related Videos

Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:February 12,2025
  • Revised:
  • Adopted:
  • Online: October 27,2026
  • Published:
Article QR Code