Characteristics and mechanisms of tension loss in the helical wrapping wires of main cables in suspension bridges
CSTR:
Author:
Affiliation:

(1.Shaanxi Union Research Center of University and Enterprise for Bridge Intelligent Construction, Xi′an 710199, China; 2.CCCC Second Highway Engineering Bureau Co., Ltd., Xi′an 710065, China; 3.School of Highway, Chang′an University, Xi′an 710064, China)

Clc Number:

U443

Fund Project:

undefined

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    To investigate the protective effectiveness of strand wrapping wire in suspension bridge main cables, a method combining refined finite element models with full-scale bridge testing was adopted to study the variations in wrapping wire tension throughout the process. Based on the validated finite element models, the impacts of the wrapping wire insertion force, main cable diameter, and main cable radial elastic modulus on tension loss were analyzed. A formula for calculating the wrapping wire insertion force, which takes into account tension loss during the wrapping wire stage, was proposed, and the existing wrapping wire process was improved. Experimental results indicate that tension loss during the wrapping wire stage is primarily caused by radial deformation of the main cable due to subsequent wrapping wire tensions. The tension loss exhibits an initial rapid decrease, followed by a slower rate, and gradually stabilizes, ranging between 26.3% and 37.3%. When the wrapping wire tension stabilizes at the test location, the wrapping wire machine advances an average distance of 25.2 cm relative to the test position. Finite element analysis results reveal that the main cable diameter and radial elastic modulus have significant effects on the proportion of wrapping wire force loss, with both factors showing an inverse proportional relationship with the force loss ratio. In the case of a main cable with a diameter of 851.9 mm, an increase in the main cable diameter by 50% reduces the wrapping wire force loss ratio from 27.8% to 13.7%, and an increase in the main cable radial elastic modulus from 1 052 MPa to 3 052 MPa reduces the force loss from 27.8% to 11.3%. Based on the experimental and finite element analysis results, a formula for calculating the insertion force that considers tension loss during the wrapping wire stage was further refined. Additionally, a novel wrapping wire process based on Mechanism of wrapping wire tension loss was introduced, which can effectively reduce tension loss during the wrapping wire process.

    Reference
    Related
    Cited by
Get Citation
Related Videos

Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:December 23,2024
  • Revised:
  • Adopted:
  • Online: September 29,2026
  • Published:
Article QR Code