Comparing research on two different numerical models of electrostatically actuated valveless micropump
CSTR:
Author:
Affiliation:

Clc Number:

TH38

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    To improve the performance of electrostatically actuated valveless micropump,simulation of its dynimic characteristics have been conducted by full electrostatic-mechanic-fluidic coupled model(CFM) and prescribed deformations model(PDM)respectively.By comparing the calculated results of diaphragm deflections,transient variations of central displacements,chamber pressures and flow rate of inlet/outlet,it can be concluded that the PDM has lower cost and inadequate precision,but some distorting dynamic characteristics may be resulted from;The FCM can predict the transient behaviors of the micropump quite well since the effects of electro-mechanical coupling and fluid-structural interaction have been considered,but the computation cost is much more expensive.

    Reference
    Related
    Cited by
Get Citation
Related Videos

Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:
  • Revised:
  • Adopted:
  • Online: May 03,2012
  • Published:
Article QR Code