(1.School of Architecture and Design, Harbin Institute of Technology, Harbin 150006, China;2.Key Laboratory of Cold Region Urban and Rural Human Settlement Environment Science and Technology(Harbin Institute of Technology), Ministry of Industry and Information Technology, Harbin 150090, China; 3.Hanfu Qidong Environmental Technology Co., Ltd., Qidong 226236, Jiangsu,China)

Fund Project:

undefined

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为解决造船业高温高湿环境下除湿效率低、能耗高及送风参数控制不精确等问题,研发一种冷凝热回收型变频热泵除湿机组,并对其性能开展系统性实验研究。该机组采用双冷凝器并联结构与全变频控制策略,具备多参数调控能力。基于焓差实验室搭建测试平台来模拟温度为35 ℃、相对湿度为70%的典型造船工况,系统分析压缩机转速、双冷凝器换热量的分配、冷凝风机频率及送风风速对机组除湿性能的影响,并采用机组能效比(COP)和单位能耗除湿量(SMER)共同作为评价指标。结果表明:在压缩机转速为3 500 r/min、冷凝风机频率为30 Hz、两器换热量配比为5.17∶1、送风风速为2.7 m/s时,COP可达4.36,SMER为4.01 kg/kWh。该机组在多种工况下均可实现对送风温湿度的精准调控,并具有良好的节能效果。本研究成果为船舶制造等对湿度控制要求严格的工业场景提供了高效节能的技术路径,并为工业除湿系统的设计与运行优化提供了理论和实验依据。

    Abstract:

    The shipbuilding industry faces challenges with low dehumidification efficiency, high energy consumption, and imprecise air supply control under high-temperature and high-humidity conditions. To address these challenges, this study developed a condensater heat recovery variable-frequency heat pump dehumidification unit and systematically evaluated its performance. The unit applied a dual-condenser parallel structure and a full-variable frequency control strategy, enabling the regulation of multi-parameters. A testing platform based on enthalpy difference laboratory was established to simulate a typical shipbuilding environment, i.e., at 35 ℃ and 70% relative humidity. The effects of compressor speed, heat exchange distribution between the two condensers, condenser fan frequency, and air supply velocity on the dehumidification performance were comprehensively examined. The performance was quantitatively assessed by coefficient of performance (COP) and specific moisture extraction rate (SMER). The results showed that optimal performance with COP of 4.36 and SMER of 4.01 kg/kWh was achieved at a compressor speed of 3 500 r/min, a condenser fan frequency of 30 Hz, a condenser heat exchange ratio of 5.17∶1, and an air supply velocity of 2.7 m/s. The unit demonstrated precise control of temperature and humidity under various operational conditions and exhibited excellent energy efficiency. The findings will provide an effective and energy-saving technical solution for industrial applications requiring strict humidity control, such as shipbuilding, and offer both theoretical and experimental support for the design and optimization of industrial dehumidification systems.