冷弯型钢腹板加劲双肢拼合短柱受力性能
CSTR:
作者:
作者单位:

(1.华北水利水电大学 土木与交通学院,郑州 450045;2.长安大学 土木工程与智能建造学院,西安 710018)

作者简介:

李艳春(1992—),女,副教授,硕士生导师;周天华(1963—),男,教授,博士生导师;李伟华(1971—),女,教授,博士生导师

通讯作者:

中图分类号:

TU398

基金项目:

河南省科技攻关项目(242102321151);河南省高等学校重点科研项目(23A560011);河南省基础设施腐蚀防控重点实验室开放基金(HNICP202408);河南省杰出青年科学基金(242300421014);河南省科技攻关项目(242102321152);内蒙古自治区自然科学基金青年基金(2025SHZR1887);河南省自然科学基金青年基金(252300423421)


Mechanical performance of cold-formed steel web-stiffened double-limb built-up short columns
Author:
Affiliation:

(1.School of Civil Engineering and Transportation, North China University of Water Resources and Electric Power, Zhengzhou 450045, China; 2.School of Civil Engineering and Smart Construction, Chang′an University, Xi′an 710018, China)

Fund Project:

undefined

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为研究冷弯型钢腹板加劲双肢拼合短柱的受力性能,通过试验研究、数值模拟和理论分析相结合,系统考察腹板高厚比、加劲角、翼缘宽厚比和螺钉间距等参数对构件力学性能的影响,并对比中国规范GB/T 50018—2025和北美规范AISI S100—2016中有效宽度法和直接强度法的承载力预测结果。结果表明:试件主要发生畸变屈曲和畸变局部相关屈曲;极限承载力随加劲角与翼缘宽厚比增大而提高,加劲角为10°和20°时,最大提升幅度分别达22.09%和19.46%;腹板高厚比增大会导致承载力显著下降,降幅为9.45%~22.42%;螺钉间距对中长柱(如2 000 mm 和2 500 mm试件)的极限承载力影响更为显著;北美规范AISI S100—2016有效宽度法承载力计算结果更接近试验结果,而中国规范GB/T 50018—2025有效宽度法和北美规范AISI S100—2016直接强度法均偏于保守。在此基础上,结合试验和有限元数据对规范方法进行修正,提出更精确的承载力计算方法,并对其可靠性进行验证。所提出的计算方法兼顾加劲效应与拼合作用,具备较好的预测精度与适用性,为相关规范的修订和设计实践提供理论依据。

    Abstract:

    To study the mechanical performance of cold-formed steel web-stiffened double-limb built-up short columns, the effects of parameters, such as the web height-to-thickness ratio, stiffening angle, flange width-to-thickness ratio, and screw spacing, on the mechanical properties of members were systematically investigated by combining experimental research, numerical simulation, and theoretical analysis. In addition, the prediction results of bearing capacity from the effective width method and the direct strength method in the Chinese code GB/T 50018—2025 and the North American code AISI S100—2016 were compared. The results show that the specimens mainly undergo distortional buckling and distortional-local interactive buckling; the ultimate bearing capacity increases with the increase of stiffening angle and flange width-to-thickness ratio, and the maximum improvements reach 22.09% and 19.46% at stiffening angles of 10° and 20°, respectively; the increase in web height-to-thickness ratio leads to a significant decrease in bearing capacity, with a decrease ranging from 9.45% to 22.42%; the screw spacing has a more significant impact on the ultimate bearing capacity of medium-to-long columns (such as 2 000 mm and 2 500 mm specimens); the calculation results of bearing capacity using the effective width method in the North American code AISI S100—2016 are closer to the experimental results, while the effective width method in the Chinese code GB/T 50018—2025 and the direct strength method in the North American code AISI S100—2016 are both conservative. On this basis, the code methods were modified by combining the experimental and finite element data, a more accurate calculation method for bearing capacity was proposed, and its reliability was verified. The proposed calculation method takes into account both the stiffening effect and the built-up effect and has good prediction accuracy and applicability, providing a theoretical basis for the revision of relevant codes and design practice.

    参考文献
    相似文献
    引证文献
引用本文

李艳春,周天华,汪志昊,乔梦慧,王乙兵,李伟华.冷弯型钢腹板加劲双肢拼合短柱受力性能[J].哈尔滨工业大学学报,2026,58(10):95. DOI:10.11918/202507056

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2025-07-23
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2026-10-27
  • 出版日期:
文章二维码