大跨度悬索桥吊索连接件叉形耳板磨损对其疲劳寿命的影响
CSTR:
作者:
作者单位:

(1.长安大学 公路学院,西安 710064; 2.陕西铁路工程职业技术学院,陕西 渭南 714000; 3.广东省公路建设有限公司湾区特大桥养护技术中心,广州 510635;4.长安大学 工程机械学院,西安 710064)

作者简介:

王小鹏(1989—),男,博士研究生;周勇军(1978—),男,教授,博士生导师

通讯作者:

中图分类号:

U448

基金项目:

广东省交通集团科技项目(JT2021YB15)


Effect of wear on fatigue life of fork-ear plate in hanger connectors of long-span suspension bridges
Author:
Affiliation:

(1.School of Highway, Chang′an University, Xi′an 710064, China; 2.Shaanxi Railway institute, Weinan 714000, Shaanxi, China; 3.Bay Area Super Major Bridge Maintenance Technology Center of Guangdong Highway Construction Co., Ltd., Guangzhou 510635, China; 4.School of Construction Machinery, Chang′an University, Xi′an 710064, China)

Fund Project:

undefined

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为探索吊索连接件磨损产生机理,量化叉形耳板的磨损深度,评估磨损对其疲劳寿命的影响,首先,通过现场调研与磨屑检测,确定磨损损伤部位,明确磨损产生机理;然后,基于实际车流数据与GNSS监测数据分析吊索索力和吊索连接件的纵向相对角度;最后,应用Archard模型量化叉形耳板的磨损深度,并对其进行疲劳寿命评估。结果表明:吊索连接件褐红色磨屑的主要成分是Fe2O3,主要来源于叉形耳板与箱梁耳板之间的磨损,未检测到关节轴承的磨屑,吊索退扭和缆梁相对运动是造成耳板磨损的根本原因;吊索连接件纵桥向相对转角主要位于-3°~3°之间,且符合高斯分布;该桥运营5 a后,叉形耳板磨损深度约为0.207 mm,磨损深度随着时间的增长不断增大,但增长速度不断减小;运营5、10、15、20、25、30 a后,吊索连接件叉形耳板疲劳寿命分别损失了7.59%、13.08%、18.89%、23.75%、28.54%、33.23%。吊索钢丝的退扭和耳板间的磨损都会降低叉形耳板的疲劳寿命,在设计吊索连接件时应予以充分考虑。

    Abstract:

    To investigate the wear mechanism of hanger connectors, quantify the wear depth of the fork-ear plate, and evaluate its impact on fatigue life, this study first identified wear damage locations and clarified the wear mechanism through field investigations and wear debris analysis. Based on actual traffic data and GNSS monitoring data, the hanger cable force and the longitudinal relative angle of the connectors were analyzed. The Archard model was then applied to quantify the wear depth of the fork-ear plate, followed by fatigue life assessment. The results indicate that the brown-red wear debris from hanger connectors primarily consists of Fe2O3, originating from wear between the fork-ear plate and the box-girder ear plate, with no wear debris from the spherical bearing detected. Hanger back-twist and cable-girder relative motion are the root causes of plate wear. The relative longitudinal rotation angle of hanger connectors predominantly ranges between -3° and 3°, following a Gaussian distribution. After 5 years of service, the wear depth of the fork-ear plates reaches approximately 0.207 mm, exhibiting progressive growth over time but with a decelerating rate. The fatigue life loss of the fork-ear plate after 5,0, 5,0, 25, and 30 years of operation is 7.59%, 13.08%, 18.89%, 23.75%, 28.54%, and 33.23%, respectively. Both hanger back-twist and wear between plates significantly reduce the fatigue life of the fork-ear plate, necessitating comprehensive consideration in the design of hanger connectors.

    参考文献
    相似文献
    引证文献
引用本文

王小鹏,周勇军,侯培源,李毅,刘一力,王博.大跨度悬索桥吊索连接件叉形耳板磨损对其疲劳寿命的影响[J].哈尔滨工业大学学报,2026,58(7):109. DOI:10.11918/202505017

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2025-05-09
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2026-09-29
  • 出版日期:
文章二维码