Abstract:To investigate the weak confinement effect of concrete-filled thin-walled steel box (CFTSB), the axial compression tests of 9 CFTSB short columns and 6 control group tests of circular concrete-filled steel tube (CFST) and ordinary reinforced concrete (RC) short columns are carried out. The mechanical behaviors such as failure mode, load-displacement curve, ultimate bearing capacity, composite strength, axial compression stiffness, and sectional strain distribution were obtained, and the weak confinement effect of CFTSB and the deformation coordination relationship between thin-walled steel box and concrete are described in detail by comparing with circular CFST and ordinary RC components. Based on the contribution of thin-walled steel box to the strength improvement of concrete, an axial compressive capacity calculating method of CFTSB short column with weak confinement effect is established. The results show that the ultimate bearing capacity and axial compression stiffness increase with the increase of steel ratio and confinement coefficient, but decrease with the increase of width-to-thickness ratio. Under the weak confinement effect, the thin-walled steel box partially buckled at 30%-40% of the ultimate load, and then the deformation of the steel box and concrete appeared uncoordinated phenomenon. The concrete is crushed when it reached ultimate state, and the bearing capacity declined rapidly because of the decrease of effective bearing area, but the ductility during later period is better maintained by the steel box. In the case of small steel ratio, the mechanical behavior of CFTSB and CEST is similar in elastic and elastic-plastic stage as well as similar ultimate bearing capacity and axial compressive stiffness, but the circular section shows ductile failure and the constraint effect of falling stage is better than that of the rectangular section. The bearing capacity and stiffness of CFTSB are about 15% and 5% higher than that of ordinary RC, respectively, and the construction does not need to tie steel bars and install and disassemble formworks. The proposed bearing capacity calculation method is proved to be reliable and can provide useful guidance for the design of CFTSB structure.