(1.College of Architecture and Civil Engineering, Beijing University of Technology, Beijing 100124, China; 2.School of Civil Engineering and Communication, North China University of Water Resources and Electric Power, Zhengzhou 450046, China; 3.Architectural Design and Research Institute of Tsinghua University Co. Ltd., Beijing 100084, China; 4.China Building Technique Group Co. Ltd., Beijing 100013, China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为研究装配式钢框架–带肋薄墙板结构的抗震性能,设计制作了一个两层两跨的足尺房屋模型,并对其展开了12个工况组的振动台试验. 试验选用El Centro波、Taft波和人工波,地震动加速度峰值(peak ground acceleration, PGA)从0.07 g逐级增长至1.2 g.研究了模型在各工况下的破坏特征、动力特性和地震响应. 结果表明:8度基本地震动时模型处于弹性阶段,8度罕遇地震动时模型损伤集中于装配式薄墙板,而钢框架应变较低. 随着PGA增大,薄墙板作为结构的第一道抗震防线逐渐开裂变形,使得结构刚度逐渐退化,而钢框架损伤轻微. 最终PGA达到1.2 g时模型X向、Y向抗侧刚度分别下降37.8%和33.6%. 试验过程结构阻尼比介于4.29%~7.19%,呈逐渐增长的趋势;各楼层加速度放大系数介于0.93~2.46,低于传统刚性结构. 模型在8度多遇、罕遇地震动时的最大层间位移角分别为1/868和1/220,满足规范限值要求;在9度极罕遇地震动时最大层间位移角达到1/71而模型未倒塌,表明结构具有良好的抗震性能,可在高设防烈度地区应用.

    Abstract:

    To investigate the seismic performance of prefabricated steel frame structure with ribbed thin walls, a full-scale two-story two-span structural model was designed and constructed, and shaking table tests of 12 test groups were performed. Three seismic waves, i.e., El Centro wave, Taft wave, and an artificial wave, were selected for the tests. Peak ground acceleration (PGA) increased from 0.07 g to 1.2 g gradually during the tests process. Failure characteristics, dynamic characteristics, and seismic responses of the model were studied under different working conditions. Results show that the model was in elastic state under frequent ground motion of 8 degrees, and the damage of the model mainly occurred in the ribbed thin walls, while the strain of the steel frame was low under rare ground motion of 8 degrees. With the increase of PGA, the thin walls cracked gradually, and the lateral stiffness of the model degraded gradually, while minor damage occurred in the steel frame. When PGA reached 1.2 g, the lateral stiffness of the model decreased by 37.8% in X direction and 33.6% in Y direction. During the whole tests process, the damping ratio of the model increased gradually between 4.29% and 7.19%, and the acceleration magnification factor of the model was between 0.93 and 2.46, which was obviously lower than that of traditional rigid structure. The maximum inter-story drift ratios of the model under frequent ground motion and rare ground motion of 8 degrees were 1/868 and 1/220, which meet the drift ratio limits according to the design code. The maximum inter-story drift ratio of the model under very rare ground motion of 9 degrees was 1/71, and there was no danger of collapse, indicating good seismic performance. Hence, prefabricated steel frame structure with ribbed thin walls can be applied in high seismic fortification intensity regions.