    摘要:

    为了得到U型翅片管换热器传热单元数计算式,以U型翅片管换热器为研究对象,通过建立翅片管换热模型,推导出了逆流和顺流2种流体流动趋势的传热单元数计算式(NTU计算式).分别采用推导出的传热单元数计算式(εNTU法)和前人推导出的平均温差关系式(LMTD法)计算U型翅片管传热系数,并进行对比分析.结果表明,当进水温度为45~60 ℃,热水流量为30~110 kg/h时,由εNTU法和LMTD法计算出来的翅片管传热系数相差很小.所推导出来的U型翅片管换热器传热单元数计算式是合理的.

    Abstract:

    To obtain the formulas of number of transfer unit (NTU) of U shaped fintube heat exchangers, a U shaped fintube heat exchanger is taked as research object. Approximate NTU formulas of number of transfer unit are derived by establishing heat transfer model of U shaped fintube when the trend of two flows in fintube heat exchanger is counter and parallel, respectively. Subsequently, the heat transfer coefficients of fintube are compared and analyzed by effectivenessnumber of transfer unit method (εNTU method) and logarithm mean temperature difference method (LMTD method) when inlet water temperature is from 45 ℃ to 60 ℃ and water flow rate is from 30 kg/h to 110 kg/h. The results show that, the difference of the heat transfer coefficients respectively calculated by εNTU method and LMTD method is so small that these NTU formulas are valid

    参考文献
    相似文献
    引证文献
引用本文

吴小舟,赵加宁. U型翅片管换热器传热单元数计算式[J].哈尔滨工业大学学报,2012,44(4):71. DOI:10.11918/j. issn.0367-6234.2012.04.015

复制
分享
相关视频

文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2012-05-04
  • 出版日期:
文章二维码